计及系统过电压的直流配电网接地方式选择与绝缘配置
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TM726

基金项目:

国家重点研发计划资助项目(2018YFB0904700);国家电网有限公司科技项目(SGJS0000YJJS1801250)


Grounding mode selection and insulation configuration of DC distribution network considering system overvoltage
Author:
Affiliation:

Fund Project:

National Key Research and Development Program of China

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    过电压特性与系统接地方式密切相关,对关键设备选取、设计具有重要意义,但目前在直流配电网中结合过电压分析进行接地方式选择的研究仍不完善。文中首先基于模块化多电平换流器(modular multi-level converter,MMC)型±10 kV双端直流配电网分析过电压产生机理,并通过PSCAD/EMTDC平台的故障仿真,对比3种典型接地方式下系统关键位置的过电压峰值。然后,提出综合故障恢复能力、经济性、电压稳定性、过电压峰值作为指标进行接地方式的选择,评估得出交流侧变压器中性点经电阻接地、直流侧不接地为所研究系统的优选接地方式。最后,基于荷电率计算设计方法确定相应的避雷器参数与配置方案,并通过仿真进行了有效性验证。研究结论为直流配电网接地方式选择与绝缘配置提供了参考。

    Abstract:

    The characteristics of overvoltage are closely related to the system grounding mode,which is of great significance to the selection and design of key equipment. However,the research on grounding mode selection combined with overvoltage analysis in DC distribution network is still imperfect. Firstly,the mechanism of overvoltage generation is analyzed for ±10 kV dual-terminal DC distribution network based on modular multi-level converter (MMC),and the overvoltage peak values at key positions of the system under three typical grounding modes are compared by fault simulation in PSCAD/EMTDC. Then,the fault recovery ability,economy,voltage stability and overvoltage peak value are proposed as the indexes for the comprehensive selection of grounding mode. Grounding by resistance through neutral point of the transformer in AC side and ungrounding in DC side is evaluated as the preferred grounding mode of the studied system. Finally,the arrester parameters and configuration scheme are determined based on the chargeability calculation design method,and the validity is verified by simulation. References for the selection of grounding mode and insulation configuration of DC distribution network are supplied by the research.

    参考文献
    相似文献
    引证文献
引用本文

刘鉴雯,吴在军,曹骁勇,杨景刚,陈庆,张勋友.计及系统过电压的直流配电网接地方式选择与绝缘配置[J].电力工程技术,2023,42(3):19-26

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-11-23
  • 最后修改日期:2023-02-09
  • 录用日期:2021-06-15
  • 在线发布日期: 2023-05-19
  • 出版日期: 2023-05-28