超低排放改造前后SCR脱硝装置性能评价分析
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Comparative Research the Performance of SCR Denitrification Device Before and After the Ultra-low Emission Retrofit in Coal-fired Units
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    选取2台燃煤机组进行实测,分析了超低排放改造前后选择性催化还原技术(selective catalytic reduction,SCR)脱硝装置出口NOx浓度、氨逃逸率以及烟气在线监测系统所测SCR脱硝出口与烟囱入口NOx浓度;同时,分析了超低排放改造机组的催化剂、空预器垢样。结果表明,机组排放超低改造后存在NOx浓度分布均匀性变差和逃逸氨浓度急剧增加问题,并由此造成空预器硫酸氢铵堵塞严重,催化剂活性成分流失较为严重,硫酸盐和碱土金属元素含量上升明显。为解决上述问题,文中提出多点监测、喷氨优化、催化剂定期测试和空预器冷端更换镀搪瓷元件等措施。

    Abstract:

    Two different types of coal-fired units are selected to compare the NOxconcentration,the ammonia escape rate and the NOxconcentration of the SCR denitrification device outlet and the chimney inlet measured by CEMS before and after the ultra-low transformation.At the same time,on the ultra-low emissions after the transformation of the air preheater dust and catalyst samples are analyzed.The results show that after the ultra-low emission of the unit,there are some problems that the bad uniformity of the NOxconcentration distribution and the increase of the escaping ammonia concentration,resulting in serious ammonium hydrogen sulfate blockage in air preheat heat.Catalyst active component of velocity is relatively serious,sulfate and alkaline earth metal elements content increased significantly.In order to solve the above problems,it is proposed to adopt multipoint monitoring,spray ammonia optimization,catalyst regularly tested,air-conditioner cold-end replacement of enamel-enriched elements and other measures.

    参考文献
    相似文献
    引证文献
引用本文

马大卫,何军,王正风,张本耀,查智明.超低排放改造前后SCR脱硝装置性能评价分析[J].电力工程技术,2018,37(4):143-148

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2018-03-16
  • 最后修改日期:2018-04-28
  • 录用日期:2018-03-20
  • 在线发布日期: 2018-07-26
  • 出版日期: