    摘要:

    为降低NOx排放,某电厂对其超临界对冲旋流燃烧锅炉进行了低氮改造,改造后NOx排放质量浓度平均降幅达到50%以上,但锅炉燃烧器周围及燃尽风区域均发生严重结渣问题。在现场测试和分析燃烧器特性的基础上,找出了锅炉结渣的原因,通过变旋流强度试验、变煤粉细度试验、变氧量试验及变燃尽风风量试验,解决了锅炉结渣问题。

    Abstract:

    In order to reduce NOx emission,technical retrofit of low NOx combustion had been carried out for opposed-firing supercritical boiler with swirl burner in a power plant.After retrofit the mass concentration of NOx emission declined by more than 50% compared with the test results before retrofit.But the serious slagging was found and research was conducted to analyse the reason of the slagging based on testing and analysing the characteristics of the new burner.The serious slagging problem was solved by a series of experiments such as changing the swirl intensity of secondary air,fineness of pulverized coal,oxygen volumetric fraction and flow rate of over-fire air (OFA) etc.